Products Detail
OUTPUT VALUES
| Standby Power | Voltage | 231/400 |
| Standby Power | kVA | 660 |
| Standby Power | kW | 528 |
| Standby Power | Amper | 954 |
| Prime Power | Voltage | 231/400 |
| Prime Power | kVA | 600 |
| Prime Power | kW | 480 |
| Prime Power | Amper | 867 |
DIMENSIONS & WEIGHT
| Without Canopy | Width | 1500 mm |
| Without Canopy | Length | 3000 mm |
| Without Canopy | High | 1700 mm |
| Without Canopy | Weight | 4360 kg |
| Without Canopy | Fuel Tank Capacity | 1000 lt |
| With Canopy | Width | 1500 mm |
| With Canopy | Length | 3500 mm |
| With Canopy | High | 2300 mm |
| With Canopy | Weight | 5540 kg |
| With Canopy | Fuel Tank Capacity | 1000 lt |
ALTERNATOR INFORMATIONS
| Standby Power (kVa/kw) | 660/528 |
| Prime Power (kVa/kw) | 600/480 |
| Brand | Leroy Somer |
| Output Voltage (V) | 231/400 |
| Frequency (Hz) | 50 |
| Stationary Vol. Regulation(±) | 0,01 |
| Short Circuit Current | %300 (10 sec) |
| Insulation | H |
| Protection | IP23 |
| E ciency (%) | 95 |
| Overloading | 110% for 1 hour |
| Power Factor (cos Q=0.8) | 0,8 |
| Tot. Harmonic Dist. Rate | <2 % |
| Connection Type | Star |
| Number of Pole | 4 |
| Number of Bearing | Single |
DIESEL ENGINE
| Brand | Perkins |
| Model | 2806A-E18TAG1 |
| Max. Total Output Pow. (kWm/hp) | 574/770 |
| Cylinder Displacement (lt) | 18,1 |
| Cylinder Orientation | 6 Single Line |
| Bore x Stroke(mm*mm) | 145*183 |
| Compression Ratio | 14,5;1 |
| Governor Type | Electronic |
| Rotation | 1500 RPM |
| Aspiration System | Turbo AAC |
| Injection | Direct |
| Cooling System | Water Cooled |
| Electrical System(V DC) | 24 |
| Oil Capacity (lt) | 62 |
| Engine Coolant Capacity (lt) | 61 |
| Fuel Cons. %50 (lt/h) | 53 |
| Fuel Cons. %75 (lt/h) | 76 |
| Fuel Cons. %100 (lt/h) | 100 |